Single-Pole Short Circuit
Combined temporary overvoltages due to single-pole short-circuit and Ferranti effect
The paper presents the determination of combined temporary overvoltages that appear on healthy phases of long unloaded lines in the …
Petar Sarajčev
,
Dario Miskovic
Cite
Analysis of conditions at disconnected SCC triplet of the double cable line
The paper presents analyses of current and voltage states in the screens of a disconnected triplex of single-core cables – and due to …
Petar Sarajčev
,
Irena Rajic
Cite
Distribution of single-pole short-circuit currents in passive elements of multy-cable systems
The paper presents a mathematical model for analyzing the distribution of single-pole short-circuit currents (SCC) in passive parts …
Irena Rajic
Cite
Analysis of the influence of 110 kV cable connection of the TS 110/20(10) kV Dugopolje on neighboring telecommunication lines
The paper presents an analysis and associated numerical calculations of the electromagnetic impact of the 110 kV cable connection TS …
Petar Sarajčev
Cite
Selection of the grounding method of the MV network 10(20) kV supplied from the TS 110/10(20) kV Srd
The study provides detailed analyses and appropriate calculations on which the proposal for selecting the grounding method for the MV …
Ivan Sarajcev
,
Petar Sarajčev
Cite
Software package EarthCAD Ver. 1.6
The EarthCAD software package consists of two units that exchange information with each other. The first unit consists of a part of the …
Petar Sarajčev
Cite
Analysis of adverse conditions at temporary working sites of the conveying tunnels for the RHPP "Velebit", HPP "Orlovac", HPP "Zakucac" and HPP "Kraljevac"
The paper analyzed and proposed a solution to the problem of meeting safety conditions at temporary work sites for the rehabilitation …
Ivan Sarajcev
,
Petar Sarajčev
Cite
Analysis of transformer TR2 in TS 110/35/10 kV Makarska relay protection tripping due to fault in the incident 110 kV transmission network
In the paper, an analysis of the possibility of the operation of the protection of the transformer TR2 in TS 110/35/10 kV Makarska was …
Petar Sarajčev
Cite
Numerical computation and dangerous voltages verification of the earthing system for the Pump Station Busko Blato
The paper presents a numerical calculation of the existing grounding system of the 110 kV switchgear at the Busko Blato substation, and …
Slavko Vujević
,
Petar Sarajčev
Cite
Influence of temporary overvoltages on the dry band arcing on ADSS fiber optic cable installed on pylons of high voltage overhead line
The paper presents a numerical calculation of the influence of temporary overvoltages (TOV) on the occurrence and magnitude (amplitude) …
Matislav Majstrovic
,
Petar Sarajčev
Cite
»
Cite
×